Outcomes and treatment strategy of transcatheter aortic valve replacement with balloon-expandable valve in borderline-size annulus.
Toshiaki IsogaiNikolaos SpiliasBeka BakhtadzeNabil SabbakKara J DenbyHabib LayounAnkit AgrawalShashank ShekharJames J YunRishi PuriSerge C HarbGrant W ReedAmar KrishnaswamySamir R KapadiaPublished in: Cardiovascular revascularization medicine : including molecular interventions (2024)
Borderline-size annulus is not associated with higher risk of adverse outcomes after BEV-TAVR. However, the larger-valve strategy for borderline-size annulus is associated with higher PPI risk, suggesting a greater risk of injury to the conduction system.