Login / Signup

Accelerating the Laboratory Testing Capacity through Saliva Pooling Prior to Direct RT-qPCR for SARS-CoV-2 Detection.

Maria Mardalena Martini KaisarSheila JonnatanTria Asri WidowatiHelen KristinSuraj Rajan VasandaniCaroline MahendraSoegianto Ali
Published in: Diagnostics (Basel, Switzerland) (2022)
The testing capacity of the laboratory is paramount for better control of the pandemic caused by SARS-CoV-2. The pooling method is promising to increase testing capacity, and the use of direct NAAT-based detection of SARS-CoV-2 on a non-invasive specimen such as saliva will ultimately accelerate the testing capacity. This study aims to validate the pooling-of-four method to quadruple the testing capacity using RNA-extraction-free saliva specimens. In addition, we intend to investigate the preferable stage of pooling, including pre- or post-heating. The compatibility of this approach was also tested on five commercial kits. Saliva specimens stored at -80 °C for several months were proven viable and were used for various tests in this study. Our findings revealed that pooling-of-four specimens had an overall agreement rate of 98.18% with their individual testing. Moreover, we proved that the pooling procedure could be conducted either pre- or post-heating, with no discordance and no significant difference in Ct values generated. When compared to other commercial detection kits, it demonstrated an overall agreement greater than 85%, which exhibits broad compatibility and ensures easy adaptability in clinical settings. This method has been proven reliable and increases the testing capacity up to fourfold.
Keyphrases
  • sars cov
  • respiratory syndrome coronavirus
  • coronavirus disease
  • magnetic resonance
  • dual energy