Predictive power of extubation failure diagnosed by cough strength: a systematic review and meta-analysis.

Jun DuanXiaofang ZhangJianping Song
Published in: Critical care (London, England) (2021)
Weak cough is associated with increased extubation failure. Cough peak flow is superior to the SCSS for predicting extubation failure. However, both show moderate power for predicting extubation failure.
Keyphrases
  • cardiac surgery
  • mechanical ventilation
  • respiratory failure
  • acute kidney injury
  • intensive care unit
  • acute respiratory distress syndrome
  • high intensity