Energy-based devices and hyaluronic acid filler, polymer filler, and threads: Cadaveric study.
Hee-Jin KimPublished in: Journal of cosmetic dermatology (2024)
The findings suggest that the thickness and composition of fillers significantly influence heat penetration. Thick PCL fillers act as a thermal barrier, whereas thin PCL fillers allow deeper heat penetration. Hyaluronic acid fillers do not impede heat transfer, regardless of their physical properties. PDO threads do not exhibit any notable thermal resistance. These insights are essential for optimizing the safety and efficacy of combined filler and energy-based device treatments in esthetic medicine.