Standardization and Validation of Brachytherapy Seeds' Modelling Using GATE and GGEMS Monte Carlo Toolkits.
Konstantinos P ChatzipapasDimitris PlachourisPanagiotis PapadimitroulasKonstantinos A MountrisJulien BertDimitris VisvikisDimitris MihailidisGeorge C KagadisPublished in: Cancers (2021)
This study aims to validate GATE and GGEMS simulation toolkits for brachytherapy applications and to provide accurate models for six commercial brachytherapy seeds, which will be freely available for research purposes. The AAPM TG-43 guidelines were used for the validation of two Low Dose Rate (LDR), three High Dose Rate (HDR), and one Pulsed Dose Rate (PDR) brachytherapy seeds. Each seed was represented as a 3D model and then simulated in GATE to produce one single Phase-Space (PHSP) per seed. To test the validity of the simulations' outcome, referenced data (provided by the TG-43) was compared with GATE results. Next, validation of the GGEMS toolkit was achieved by comparing its outcome with the GATE MC simulations, incorporating clinical data. The simulation outcomes on the radial dose function (RDF), anisotropy function (AF), and dose rate constant (DRC) for the six commercial seeds were compared with TG-43 values. The statistical uncertainty was limited to 1% for RDF, to 6% (maximum) for AF, and to 2.7% (maximum) for the DRC. GGEMS provided a good agreement with GATE when compared in different situations: (a) Homogeneous water sphere, (b) heterogeneous CT phantom, and (c) a realistic clinical case. In addition, GGEMS has the advantage of very fast simulations. For the clinical case, where TG-186 guidelines were considered, GATE required 1 h for the simulation while GGEMS needed 162 s to reach the same statistical uncertainty. This study produced accurate models and simulations of their emitted spectrum of commonly used commercial brachytherapy seeds which are freely available to the scientific community. Furthermore, GGEMS was validated as an MC GPU based tool for brachytherapy. More research is deemed necessary for the expansion of brachytherapy seed modeling.
Keyphrases
- high dose
- monte carlo
- low dose
- stem cell transplantation
- radiation therapy
- molecular dynamics
- computed tomography
- locally advanced
- high resolution
- type diabetes
- atrial fibrillation
- clinical practice
- mental health
- machine learning
- adipose tissue
- big data
- insulin resistance
- metabolic syndrome
- magnetic resonance
- skeletal muscle
- ultrasound guided
- positron emission tomography
- deep learning