Usefulness of ICD electrograms analysis to distinguish endocardial vs epicardial ventricular tachycardia in arrhythmogenic right ventricular cardiomyopathy.
Santhisri KodaliYasuhiro ShiraiDavid J CallansErica S ZadoFrancis E MarchlinskiPasquale SantangeliPublished in: Journal of cardiovascular electrophysiology (2019)
Far-field to near-field ICD VEGM timing may be used to predict ENDO vs EPI VT in ARVC before ablation, indicating an ENDO origin if the timing is less than or equal to 30 ms and an EPI origin if greater than or equal to 60 ms.