Membrane-based therapeutic plasma exchange: Proposed techniques for preventing filter failure.

Ibrahim ElaliDeep PhachuNick CoombsMamta ShahJordan DeanLalarukh HaiderYanlin WangAndre A Kaplan
Published in: Journal of clinical apheresis (2023)
Rate of filter failure in mTPE can be reduced by implementing several therapeutic interventions including pre-filter heparin and pre-filter saline solution. These interventions were not associated with any clinically significant adverse events. Despite the above-mentioned interventions, large plasma volume exchanges of ≥3 L can negatively impact filter life.