Novel Landmark for Cervical Pedicle Screw Insertion Point from Computed Tomography-Based Study.

Kazuya NishizawaKanji MoriAkira NakamuraShinji Imai
Published in: Asian spine journal (2017)
The N-line was frequently located at the level of the pedicle of each cervical spine in the sagittal plane. The superomedial edge of the lamina could be a new landmark for the insertion point of the cervical pedicle screw.