Login / Signup

Positive flow cytometry crossmatch with discrepant antibody testing results following COVID-19 vaccination.

Qingyong XuParmjeet S RandhawaDennis HelmickJon S LomagoAmit D TevarAdriana Zeevi
Published in: American journal of transplantation : official journal of the American Society of Transplantation and the American Society of Transplant Surgeons (2021)
The impact of COVID-19 vaccination on the alloimmunity of transplant candidates is unknown. We report a case of positive B cell flow cytometry crossmatch in a patient waiting for second kidney transplantation, 37 days after receiving the COVID-19 vaccine. The preliminary crossmatch, using sample collected before COVID-19 vaccination, was negative. The antibodies to mismatched donor HLA-DR7 were detected only with multi-antigen beads but not with single-antigen beads, excluding possible prozone effects in solid-phase antibody assays. The crossmatches were positive with HLA-DR7-positive surrogates (n = 2) while negative with HLA-DR7-negative surrogates (n = 3), which confirms the HLA-DR7 alloreactivity. The antigen configurations on B lymphocytes are similar to that on the multi-antigen beads while distinct from the single-antigen beads. HLA-DR7 was the repeating mismatched antigen with the failing first kidney allograft. The newly emerged antibody to HLA-DR7 probably is the consequence of bystander activation of memory response by the COVID-19 vaccination. This case highlights the importance of verifying allo-sensitization history and utilizing multiple assays, including cell-based crossmatch and solid-phase assays with multi-antigens. COVID-19 immunization may deserve special attention when assessing the immunological risk before and after organ transplantation.
Keyphrases
  • coronavirus disease
  • sars cov
  • flow cytometry
  • editorial comment
  • kidney transplantation
  • respiratory syndrome coronavirus
  • high throughput
  • stem cells
  • working memory
  • mesenchymal stem cells
  • case report
  • bone marrow