Monolithic mtesla-level magnetic induction by self-rolled-up membrane technology.

Wen HuangZhendong YangMark D KramanQingyi WangZihao OuMiguel Muñoz RojoAnanth Saran YalamarthyVictoria ChenFeifei LianJimmy H NiSiyu LiuHaotian YuLei SangJulian MichaelsDane J SieversJ Gary EdenPaul V BraunQian ChenSongbin GongDebbie G SeneskyEric PopXiuling Li
Published in: Science advances (2020)
Monolithic strong magnetic induction at the mtesla to tesla level provides essential functionalities to physical, chemical, and medical systems. Current design options are constrained by existing capabilities in three-dimensional (3D) structure construction, current handling, and magnetic material integration. We report here geometric transformation of large-area and relatively thick (~100 to 250 nm) 2D nanomembranes into multiturn 3D air-core microtubes by a vapor-phase self-rolled-up membrane (S-RuM) nanotechnology, combined with postrolling integration of ferrofluid magnetic materials by capillary force. Hundreds of S-RuM power inductors on sapphire are designed and tested, with maximum operating frequency exceeding 500 MHz. An inductance of 1.24 μH at 10 kHz has been achieved for a single microtube inductor, with corresponding areal and volumetric inductance densities of 3 μH/mm2 and 23 μH/mm3, respectively. The simulated intensity of the magnetic induction reaches tens of mtesla in fabricated devices at 10 MHz.