Cervical Spine Motion Requirements From Night Vision Goggles May Play a Greater Role in Chronic Neck Pain than Helmet Mass Properties.
Jeff M BarrettLaura A HealeySteven L FischerJackie D ZehrPublished in: Human factors (2022)
Every 30° of MM increased compression by 57 to 105 N. The reduction of the moment of inertia by 16% in the CWL did not reduce reaction forces. Joint loads scaled proportionately with head-supported weight by a factor of 2.05. The magnitudes of loads suggest a cumulative loading pathway for CNP development.