Assessing the Structural Validity of the Knee Injury and Osteoarthritis Outcome Score Scale.

Dylan T QuintanaMadeline P CasanovaAdam C CadyRussell T Baker
Published in: Healthcare (Basel, Switzerland) (2024)
The KOOS failed to meet model fit recommendations. The KOOS SF-12 met model fit recommendations, maintained a multi-factorial structure, and was invariant across all tested groups. The KOOS did not demonstrate sound structural validity. A refined KOOS SF-12 model that met recommended model fit indices and invariance testing criteria was identified. Our findings provide initial support for a multidimensional KOOS structure (i.e., KOOS SF-12) that is a more psychometrically sound instrument for measuring patient-reported knee health.