Insights into Paraben Adsorption by Metal-Organic Frameworks for Analytical Applications.
Providencia González-HernándezAdrián Gutiérrez-SerpaAna B LagoLaura EstévezJuan H AyalaVerónica PinoJorge PasánPublished in: ACS applied materials & interfaces (2021)
Metal-organic frameworks (MOFs) are attractive materials used as sorbents in analytical microextraction applications for contaminants of emerging concern (CECs) from environmental liquid matrices. The demanding specs for a sorbent in the analytical application can be comprehensively studied by considering the interactions of the target analytes with the frameworks by the use of single-crystal X-ray diffraction, computational analysis, and adsorption studies, including the kinetic ones. The current study intends a better understanding of the interactions of target CECs (particularly, propylparaben (PPB) as a model) and three Zn-based layered pillared MOFs: CIM-81 [Zn2(tz)2(bdc)] (Htz = 1,2,4-triazole and H2bdc = 1,4-benzenedicarboxylic acid) and their amino derivatives [Zn2(NH2-tz)2(bdc)] CIM-82 and [Zn2(tz)2(NH2-bdc)] CIM-83 (NH2-Htz = 3-amino-1,2,4-triazole and NH2-H2bdc = 2-amino-1,4-benzenedicarboxylic acid). The crystal structures of the two solvate compounds (dma@CIM-81 (dma = dimethylacetamide) and acetone@CIM-81) were solved by single-crystal X-ray diffraction to determine the points of interaction between the framework and the guest molecules. They also served as a starting point for the computational modeling of the PPB@CIM-81 compound, showing that up to two PPB molecules can be hosted in one of the pores, while only one can be trapped in the second pore type, leading to a maximum theoretical capacity of 291.9 mg g-1. This value is close to the value obtained by the adsorption isotherm experiment for CIM-81 (283 mg g-1). This value is, by far, higher than those previously reported for other materials for the removal of PPB from water, and also higher than the experimental values obtained for CIM-82 (54 mg g-1) and CIM-83 (153 mg g-1). The kinetics of adsorption is not very fast, with uptake of about 40% in 3 h, although a 70% release in methanol is achieved in 1 h. In addition, a further comparison of performance in analytical microextraction (requiring only 10 mg of CIM-81) was carried out together with chromatographic analysis to support all insights attained, with the method being able to monitor CECs as low as μg L-1 levels in complex environmental water samples, thus performing successfully for water monitoring even in multicomponent scenarios.
Keyphrases
- metal organic framework
- ionic liquid
- liquid chromatography
- heavy metals
- aqueous solution
- room temperature
- solid phase extraction
- simultaneous determination
- high resolution
- molecularly imprinted
- liquid chromatography tandem mass spectrometry
- mass spectrometry
- gold nanoparticles
- magnetic resonance imaging
- risk assessment
- computed tomography
- ms ms
- crystal structure
- human health
- dual energy
- reduced graphene oxide