Non-locked and locked small fragment straight plates have a similar behavior in buttressing the posteromedial shear tibial plateau fragment: a biomechanical analysis of three different fixations.
Vincenzo GiordanoMauricio KfuriWilliam BelangeroAllison VenturiniAna Carolina SilvaEduardo Merjan SoaresRobinson Esteves PiresHilton A KochPublished in: Journal of experimental orthopaedics (2020)
Placement of either a locked or non-locked small fragment straight plate to buttress the posteromedial shear tibial plateau fragment has a similar biomechanical behavior. When the implant is positioned to buttress the shearing fragment it maximizes biomechanical stiffness.