Transient Versus Two-Dimensional Shear-Wave Elastography in a Multistep Strategy to Detect Advanced Fibrosis in NAFLD.
Christophe CassinottoJérome BoursierAnita PaisantBoris GuiuMarie Irles-DepeClémence CanivetChristophe AubeVictor de LedinghenPublished in: Hepatology (Baltimore, Md.) (2021)
Using the same cutoff values, 2D-SWE-SSI is as accurate as VCTE for advanced liver fibrosis diagnosis in NAFLD. The three-step strategy in selected patients strongly decreased the need for liver biopsy while maintaining excellent accuracy.