Evaluation of Radiographic Contrast-Induced Nephropathy by Functional Diffusion Weighted Imaging.

Thomas Andreas ThielJulian SchweitzerTaogetu XiaEric BechlerBirte ValentinAndrea SteuweFriedrich BoegeRalf WestenfeldHans-Jörg WittsackAlexandra Ljimani
Published in: Journal of clinical medicine (2021)
Contrast-induced nephropathy (CIN) resembles an important complication of radiographic contrast medium (XCM) displayed by a rise in creatinine levels 48-72 h after XCM administration. The purpose of the current study was to evaluate microstructural renal changes due to CIN in high-risk patients by diffusion weighted (DWI) and diffusion tensor imaging (DTI). Fifteen patients (five CIN and ten non-CIN) scheduled for cardiological intervention were included in the study. All patients were investigated pre- and post-intervention on a clinical 3T scanner. After anatomical imaging, renal DWI was performed by a paracoronal echo-planar-imaging sequence. Renal clinical routine serum parameters and advanced urinary injury markers were determined to monitor renal function. We observed a drop in cortical and medullar apparent diffusion coefficient (ADC) and fractional anisotropy (FA) before and after XCM administration in the CIN group. In contrast, the non-CIN group differed only in medullary ADC. The decrease of ADC and FA was apparent even before serum parameters of the kidney changed. In conclusion, DWI/DTI may be a useful tool for monitoring high-risk CIN patients as part of multi-modality based clinical protocol. Further studies, including advanced analysis of the diffusion signal, may improve the identification of patients at risk for CIN.
Keyphrases