Spot-scanning proton therapy for early breast cancer in free breathing versus deep inspiration breath-hold.

Line Bjerregaard StickLouise Lærke NielsenCecilia Bui TrinhIhsan BahijMaria Fuglsang JensenCamilla Jensenius Skovhus KronborgStine Elleberg PetersenLinh My Hoang ThaiMay-Lin MartinsenHelle PrechtBirgitte Vrou Offersen
Published in: Acta oncologica (Stockholm, Sweden) (2024)
The median absolute reduction in dose to the heart was limited. Proton treatment in DIBH may only be relevant for a subset of these patients with the largest reduction in heart exposure.
Keyphrases
  • early breast cancer
  • heart failure
  • atrial fibrillation