Login / Signup

Success and high predictability of intraorally welded titanium bar in the immediate loading implants.

Vaniel FogliMichele CameriniLauritano DorinaFrancesco Carinci
Published in: Case reports in dentistry (2014)
The implants failure may be caused by micromotion and stress exerted on implants during the phase of bone healing. This concept is especially true in case of implants placed in atrophic ridges. So the primary stabilization and fixation of implants are an important goal that can also allow immediate loading and oral rehabilitation on the same day of surgery. This goal may be achieved thanks to the technique of welding titanium bars on implant abutments. In fact, the procedure can be performed directly in the mouth eliminating possibility of errors or distortions due to impression. This paper describes a case report and the most recent data about long-term success and high predictability of intraorally welded titanium bar in immediate loading implants.
Keyphrases
  • soft tissue
  • minimally invasive
  • electronic health record
  • coronary artery disease
  • coronary artery bypass
  • body composition
  • drug induced