Fine wire versus locking plate fixation of type C pilon fractures.
Nisarg MehtaSimon Matthew GrahamNikhil LalLauren WellsNikolaos GiotakisSelvadurai NayagamBadri NarayanPublished in: European journal of orthopaedic surgery & traumatology : orthopedie traumatologie (2021)
With correct patient selection, both ORIF and CEF offer equivalent and favourable early to mid-term outcomes with regard to deep SSI, non-union, mal-union and PTOA. Although statistically insignificant, ORIF with more than 2 plates carries a risk of superficial and deep SSI, whilst CEF is associated with a 22% pin track infection rate. These unique risks must be discussed with the patient as part of a shared decision-making process.