A method for assessment of the dynamic response of the arterial baroreflex.
Morten Asp Vonsild LundM SalomonssonT E N JonassenN-H Holstein-RathlouPublished in: Acta physiologica (Oxford, England) (2017)
The ARMAX model represents an efficient method for estimating several aspects of the baroreflex. The open-loop gain of the baroreflex was attenuated in obese-hypertensive rats compared with control, while the time response was similar. The algorithm can be applied to other species including humans.