Mirosław GozdekLukasz KuzmaEmil Julian DąbrowskiMichał JaniakMartyna PietrzakKarolina SkoniecznaMikołaj WoźnicaLidia WydeheftMaged MakhoulMatteo MatteucciRadosław LitwinowiczAdam KowalówkaWojciech WańhaMichał PasierskiDaniele RoncoGiulio MassimiFederica JiritanoDario FinaGennaro MartucciGiuseppe Maria RaffaPiotr SuwalskiRoberto LorussoPaolo MeaniMariusz Kowalewskinull null
Published in: International journal of environmental research and public health (2023)
The evidence shows good short-term outcomes of both the Evolut PRO and Evolut R prostheses, with no differences in clinical and procedural endpoints. The Evolut PRO was associated with a lower rate of moderate-to-severe PVL and major bleeding.