Login / Signup

Safely replacing a percutaneous endoscopic gastrostomy tube using a portable X-ray system at a patient's home.

Hitoshi EguchiNaoko E KatsukiKen-Ichi YamamotoMasaki Tago
Published in: BMJ case reports (2021)
An 81-year-old woman who underwent percutaneous endoscopic gastrostomy (PEG) a year before, after cerebral infarction was receiving home medical care. The first accidental PEG tube removal occurred after clinic hours, and the home-care doctor visited her home to quickly reinsert the tube. After the narrowed fistula was dilated, the tube was reinserted with a guide wire. An X-ray taken with a CALNEO Xair, which is an easily portable X-ray system launched in 2018, confirmed that the tip of the PEG tube was successfully placed in the stomach. A similar accidental removal occurred 2 months later, and we managed it in the same way. Both events were resolved with a single radiograph without significant difficulty. With in-home medical care, PEG tube replacement can be performed easily and safely with a handy portable X-ray system.
Keyphrases
  • ultrasound guided
  • high resolution
  • healthcare
  • drug delivery
  • dual energy
  • case report
  • minimally invasive
  • radiofrequency ablation