Correlation between echocardiographic estimation of right atrial pressure and invasive measurement of central venous pressure in postoperative pediatric patients with congenital heart disease: a prospective observational study.
Elaheh Malakan RadNazli ParizadehHassan RadmehrToktam SheykhianBehdad GharibAliakbar ZeinalooPublished in: The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology (2024)
The estimation of central venous pressure through a multi-parametric equation that included the ratio of the maximal diameter of the inferior vena cava to the maximal diameter of the descending aorta, the ratio of S to D velocity of the superior vena cava, the vertical diameter of the right atrium, and the acceleration rate of the A wave of the tricuspid valve demonstrated a robust correlation with invasively measured central venous pressure. To assess the accuracy of predicted pressures by this equation, further investigations are required to apply this innovative multi-parametric formula to a prospective population of pediatric patients with congenital heart disease.