A Collimator Setting Optimization Algorithm for Dual-Arc Volumetric Modulated Arc Therapy in Pancreas Stereotactic Body Radiation Therapy.
Xinyi LiQ Jackie WuManisha PaltaYou ZhangYang ShengJiahan ZhangChunhao WangPublished in: Technology in cancer research & treatment (2020)
The proposed collimator settings optimization algorithm successfully improved dosimetric performance for dual-arc pancreas volumetric modulated arc therapy plans in stereotactic body radiation therapy of pancreas. This algorithm has the capability of immediate clinical application.