Does the type of sagittal split ramus osteotomy influence fixation strength? Evaluation of the mechanical behavior of two types of fixation used in three types of sagittal split ramus osteotomy.

Soraya da Silva OliveiraPedro Henrique Mattos de CarvalhoCássio Edvard SverzutAlexandre Elias Trivellato
Published in: Oral and maxillofacial surgery (2022)
In the application of load in the inter-incisor region, there was no statistical difference between the type of osteotomy and the type of fixation used. When applying loads to molars, there was a difference for the type of osteotomy, where the Epker osteotomy with 2 modifications presented greater resistance, regardless of the type of fixation used.