Vascular refilling in hemodialysis using feedback-controlled ultrafiltration profile.
Stefanie BroszeitJoachim KronTil LeimbachJohn VolkenandtSusanne KronPublished in: The International journal of artificial organs (2024)
Despite significant differences, a feedback-controlled UF profile has no advantage over the previous refilling studies with regard to the refilling fraction because vascular refilling seems to depend mainly on the ratio of BV to ECV. This would explain the different results in studies using BV guided UF feedback programs.