Problems with Bazett QTc correction in paediatric screening of prolonged QTc interval.
Irena AndršováKaterina HnatkovaKateřina HelánováMartina ŠišákováTomáš NovotnýPetr KalaMarek MalikPublished in: BMC pediatrics (2020)
During screening for LQTS in children, the use of Bazett formula leads to a high number of false positive cases especially if the heart rates are increased (e.g. by postural manoeuvring). The use of Fridericia formula can be recommended to replace the Bazett correction not only for adult but also for paediatric ECGs.