High-resolution peripheral quantitative computed tomography in children with osteogenesis imperfecta.

David J FennimoreMaria DigbyMargaret PaggiosiPaul ArundelNick J BishopPaul DimitriAmaka C Offiah
Published in: Pediatric radiology (2020)
Bone health in children with osteogenesis imperfecta is monitored using radiographs and dual-energy X-ray absorptiometry, which have limitations. High-resolution peripheral quantitative CT can non-invasively derive bone microarchitectural data. Children with severe osteogenesis imperfecta have fragile deformed bones, and positioning for this scan can be difficult. We assessed the feasibility of high-resolution peripheral quantitative CT in nine children aged 9-15 years with osteogenesis imperfecta and compared results with dual-energy X-ray absorptiometry and with healthy controls. All nine recruited children were successfully scanned and showed no preference for either modality. It therefore appears feasible to perform high-resolution peripheral quantitative CT in children with osteogenesis imperfecta aged 9 years and older. Future studies should focus on understanding the clinical implications of the technology in this patient cohort.