Effect of emphysema on AI software and human reader performance in lung nodule detection from low-dose chest CT.

Nikos SourlosGertJan PelgrimHendrik Joost WisselinkXiaofei YangGonda de JongeMieneke RookMathias ProkopGrigory SidorenkovMarcel van TuinenRozemarijn VliegenthartPeter M A van Ooijen
Published in: European radiology experimental (2024)
• The sensitivity of nodule detection by AI was similar in emphysema and non-emphysema. • AI had more FPs/scan in emphysema compared to non-emphysema. • Sensitivity and FPs/scan by the human reader were comparable for emphysema and non-emphysema. • Emphysema and non-emphysema representation in benchmark dataset is important for validating AI.