A retrospective study on clinical and radiological outcomes of oral implants in patients followed up for a minimum of 20 years.
Bruno Ramos ChrcanovicJenö KischTomas AlbrektssonAnn WennerbergPublished in: Clinical implant dentistry and related research (2017)
Most of the implant failures occurred at the first few years after implantation, regardless of a very long follow up. MBL can be insignificant in long-term observations, but it may, nevertheless, be the cause of secondary failure of oral implants in some cases.