Very Long-Term Follow-Up in Cardiac Resynchronization Therapy: Wider Paced QRS Equals Worse Prognosis.
Patrick LeitzJulia KöbeBenjamin RathFlorian ReinkeGerrit FrommeyerChristian AndresenFatih GünerJulian WolfesPhilipp S LangeChristian EllermannLars EckardtDirk G DecheringPublished in: Journal of personalized medicine (2021)
Our data show that QRS width duration during biventricular pacing, an ECG parameter easily obtainable during LV lead placement, is an independent predictor of mortality in a long-term follow-up. Our data add further evidence that NICM and lower NYHA class are independent predictors for better outcome after CRT implantation.