Assessing the osseointegration potential of a strontium releasing nanostructured titanium oxide surface: A biomechanical study in the rabbit tibia plateau model.

Sila Cagri IslerBenjamin BellonMorten FossBenjamin Evans PippengerAndreas StavropoulosOle Zoffmann Andersen
Published in: Clinical and experimental dental research (2023)
The tested Ti-Sr-O technology failed to enhance osseointegration; however, this finding may be related to the inappropriateness of the rabbit tibia plateau model for assessing third-generation implant surface technologies, due to the limited diffusion and clearance at the disk-bone interface.
Keyphrases
  • bone mineral density
  • human health
  • finite element