Biomechanical properties of the bone during implant placement.
Ádám László NagyZsolt TóthTamás TarjányiNándor Tamás PrágerZoltán Lajos BaráthPublished in: BMC oral health (2021)
The pre-drilled bone was much weaker in both static and dynamic tests than the natural or implanted specimens. According to the results of the dynamic tests and after a certain loading cycle the implanted samples behaved the same way as the control samples, which suggests that implantation have stabilized the skeletal bone structure.