Login / Signup

Aortic Root Distortion During Balloon Angioplasty of Right Ventricular Outflow Tract Prior to Transcatheter Pulmonary Valve Implantation.

James A KuoDeborah A Schutte
Published in: Pediatric cardiology (2020)
We describe our experience with aortic root distortion in transcatheter pulmonary valve implantation (TPVI). Aortic root distortion (AD) can be observed with balloon angioplasty of the right ventricular outflow tract (RVOT), but its long-term significance is unknown. This has been a common finding in our institution, though not fully appreciated in our early experience. Retrospective review of procedural angiograms prior to TPVI and follow up imaging was performed. Between June 2012 and October 2017, 47 patients underwent catheterization to attempt TPVI. Five patients had coronary compression which precluded TPVI (one with significant AD as well). Four patients had significant AD and did not receive TPVI. Of the remaining 38 successful TPVI, 20 had adequate imaging to assess the aortic root. Four patients had severe AD, 7 had mild AD, and 9 with no AD. Severity of AI did not correlate with degree of AD. Median follow up after TPVI was 46 months (IQR 21-67). Of the 4 patients with severe AD who received TPVI, 1 has new mild AI with 78 months follow up. Of the 18 patients who received TPVI without adequate arch imaging, 2 patients have new mild AI with 86 and 75 months follow up. AD during RVOT angioplasty is a relatively common finding. In our early experience, some patients who were retrospectively identified to have severe AD received TPVI. These patients have done well, though further data is needed before considering severe AD a benign finding.
Keyphrases