Impact of cement type and abutment height on pull-off force of zirconia reinforced lithium silicate crowns on titanium implant stock abutments: an in vitro study.

Lisa MüllerAngelika RauchDaniel R ReissmannOliver Schierz
Published in: BMC oral health (2021)
Permanent cements present higher retention than semi-permanent ones, and temporary cements present the lowest values. The abutment height had a subordinate impact.