Login / Signup

Ames-2021 CO 2 Dipole Moment Surface and IR Line Lists: Toward 0.1% Uncertainty for CO 2 IR Intensities.

Xinchuan HuangDavid W SchwenkeRichard S FreedmanTimothy M J Lee
Published in: The journal of physical chemistry. A (2022)
A highly accurate CO 2 ab initio dipole moment surface (DMS), Ames-2021, is reported along with 12 C 16 O 2 infrared (IR) intensity comparisons approaching a 1-4‰ level of agreement and uncertainty. The Ames-2021 DMS was accurately fitted from CCSD(T) finite-field dipoles computed with the aug-cc-pVXZ (X = T, Q, 5) basis for C atom and the d-aug-cc-pVXZ (X = T, Q, 5) basis for O atoms, and extrapolated to the one particle basis set limit. Fitting σ rms is 3.8 × 10 -7 au for 4443 geometries below 15 000 cm -1 . The corresponding IR intensity, S Ames-2021 , are computed using the Ames-2 potential energy surface (PES), which is the best PES available for CO 2 . Compared to high accuracy IR studies for 2001 i -00001 and 3001 i -00001 bands, S Ames-2021 matches NIST experiment-based intensities [ S NIST-HIT16 or S HIT20 ] to -1.0 ± 1.3‰, or matches DLR experiment-based intensities [ S DLR-HIT16/UCL/Ames ] to 1.9 ± 3.7‰. This indicates the systematic deviations and uncertainties have been significantly reduced in S Ames-2021 . The S UCL2015 (or S HITRAN2016 ) have larger deviations (vs S DLR ) and uncertainties (vs S DLR , S NIST ) which are attributed to the less accurate Ames-1 PES adopted in UCL-296 line list calculation. The S Ames-2021 intensity of 12 C 16 O 2 and 13 C 16 O 2 is utilized to derive new absolute 13 C/ 12 C ratios for Vienna PeeDee Belemnite (VPDB) with uncertainty reduced by 1 / 3 or 2 / 3 . Further evaluation of S Ames-2021 intensities are carried out on those CO 2 bands discussed in the HITRAN2020 update paper. Consistent improvements and better accuracies are found in band-by-band analysis, except for those bands strongly affected by Coriolis couplings, or very weak bands measured with relatively larger experimental uncertainties. The Ames-2021 296 K IR line lists are generated for 13 CO 2 isotopologues, with 18 000 cm -1 and S 296 K > 1 × 10 -31 cm/molecule cutoff and then combined with CDSD line positions (except 14 C 16 O 2 ). The Ames-2021 DMS and 296 K IR line lists represent a major improvement over previous CO 2 theoretical IR intensity studies, including Ames-2016, UCL-296, and recent UCL DMS 2021 update. A real 1 permille level of agreement and uncertainty will definitely require both more accurate PES and more accurate DMS.
Keyphrases
  • high resolution
  • magnetic resonance
  • computed tomography
  • quantum dots
  • molecular dynamics
  • human health
  • contrast enhanced
  • case control