Performance of Automated ASPECTS Software and Value as a Computer-Aided Detection Tool.
Julie LambertJelle DemeestereB DewachterLesley CockmartinAnke WoutersRolf SymonsLukas BoomgaertLieselotte VandewalleLauranne ScheldemanPhilippe DemaerelRobin LemmensPublished in: AJNR. American journal of neuroradiology (2023)
Automated ASPECTS had agreement with the criterion standard similar to that of conventional ASPECTS. However, including automated ASPECTS during the evaluation of NCCT in acute stroke improved the agreement with the criterion standard and improved interrater agreement, which could, therefore, result in more uniform scoring in clinical practice.