Login / Signup

Influence of the Rinsing Postprocessing Procedures on the Manufacturing Accuracy of Vat-Polymerized Dental Model Material.

Delaram MostafaviMohammad Mujtaba MethaniWenceslao Piedra-CascónAmirali ZandinejadMarta Revilla-León
Published in: Journal of prosthodontics : official journal of the American College of Prosthodontists (2021)
None of the manufacturing workflows tested were able to manufacture a perfect match of the bar virtual design dimensions. TPM solvent group obtained higher trueness and precision values compared to the IPA solvent group. The IPA-1 subgroup that replicated the manufacturer´s recommendations obtained the highest manufacturing accuracy among the IPA subgroup. TPM solvent used in a rinsing ultrasonic bath between 3 and 4 minutes followed by a second ultrasonic clean bath between 2 and 3 minutes of the just printed vat polymerized dental model specimens obtained the highest manufacturing accuracy values.
Keyphrases
  • ionic liquid
  • oral health
  • randomized controlled trial
  • clinical trial
  • phase iii