Physiological effects of human body imaging with 300 mT/m gradients.
Malwina MolendowskaFabrizio FasanoUmesh RudrapatnaRalph KimmlingenDerek K JonesSlawomir KusmiaChantal M W TaxC John EvansPublished in: Magnetic resonance in medicine (2021)
This study evaluates the probability of eliciting magnetophosphenes during whole-body imaging using an ultra-strong gradient MRI system. It provides empirical guidance on the use of high-performance gradient systems for whole-body human MRI.