Low-pressure support vs automatic tube compensation during spontaneous breathing trial for weaning.

Nicolas TerziNicolas TerziMehdi MezidiLoredana BaboiNader ChebibHodane YonisLaurent ArgaudLeo HeunksBruno Louis
Published in: Annals of intensive care (2019)
We found that ATC was associated with higher breathing power than low PS during SBT without altering the distribution of lung ventilation.