Left heart pressures can be the key to know the limitation of left ventricular assist device support against progression of aortic insufficiency.
Kei IizukaTomohiro NishinakaNoritsugu NaitoDaichi AkiyamaYoshiaki TakewaKenji YamazakiEisuke TatsumiPublished in: Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs (2018)
Aortic insufficiency (AI) is a worrisome complication under left ventricular assist device (LVAD) support. AI progression causes LVAD-left ventricular (LV) recirculation and can require surgical intervention to the aortic valve. However, the limitations of LVAD support are not well known. Using an animal model of LVAD with AI, the effect of AI progression on hemodynamics and myocardial oxygen metabolism were investigated. Five goats (Saanen 48 ± 2 kg) underwent centrifugal type LVAD, EVAHEART, implantation. The AI model was established by placing a vena cava filter in the aortic valve. Cardiac dysfunction was induced by continuous beta-blockade (esmolol) infusion. Hemodynamic values and myocardial oxygen extraction ratio (O2ER) were evaluated while changing the degree of AI which was expressed as the flow rate of LVAD-LV recirculation (recirculation rate). Diastolic aortic pressure was decreased with AI progression and correlated negatively with the recirculation rate (p = 0.00055). Systolic left ventricular pressure (LVP) and mean left atrial pressure (LAP) were increased with AI progression and correlated positively with the recirculation rate (p = 0.010, 0.023, respectively). LVP and LAP showed marked exponential increases when the recirculation rate surpassed 40%. O2ER was also increased with AI progression and had a significant positive correlation with the recirculation rate (p = 0.000043). O2ER was increased linearly, with no exponential increase. AI progression made it difficult to reduce the cardiac pressure load, worsening myocardial oxygen metabolism. The exponential increase of left heart pressures could be the key to know the limitation of LVAD support against AI progression.
Keyphrases
- left ventricular
- left ventricular assist device
- aortic valve
- artificial intelligence
- aortic stenosis
- left atrial
- heart failure
- hypertrophic cardiomyopathy
- anaerobic digestion
- transcatheter aortic valve replacement
- cardiac resynchronization therapy
- aortic valve replacement
- mitral valve
- transcatheter aortic valve implantation
- acute myocardial infarction
- randomized controlled trial
- machine learning
- atrial fibrillation
- vena cava
- estrogen receptor
- low dose
- high resolution
- endoplasmic reticulum
- pulmonary artery
- mass spectrometry