An isothermal CRISPR-based diagnostic assay for Neisseria gonorrhoeae and Chlamydia trachomatis detection.
Hao LuoLihong ZengXiaona YinYuying PanJianjiang YangMingjing LiuXiaolin QinZhanqin FengWentao ChenHe-Ping ZhengPublished in: Microbiology spectrum (2023)
The occurrence of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) is increasing worldwide, particularly in low- and middle-income countries. In cases where most infections are asymptomatic and remain in a coinfection condition. It may cause missed detections or the severe subsequent symptoms. Accurate diagnosis and convenient screening are essential for disease control. However, molecular diagnostics for CT/NG predominantly rely on polymerase chain reaction (PCR)-based detection, which requires special devices and conditions. Here, we developed an isothermal CRISPR-based CT/NG dual-target detection system by pairing recombinase polymerase amplification (RPA) and CRISPR-Cas12a/13a detection. Multiplex RPA can amplify NG and CT simultaneously, and a single-pot reaction with the Cas12a/13a can be performed for further recognizing the amplified target, driving the cleavage of the corresponding fluorescence reporter separately; thus, the signal can be monitored in different channels. This CRISPR-based CT/NG detection system achieved analytical sensitivities of 10° copies/μL for both synthetic CT/NG dsDNA and exhibited no cross-reaction with other species. In tests on 88 clinical samples, our CRISPR-based assay showed excellent agreement with the commercial assay Roche Cobas 4800 (100% accuracy for NG, 94.32% accuracy for CT, and 97.73% accuracy for CT/NG coinfection) and showed higher positive percent agreement, negative percent agreement, and accuracy than those reported for TaqMan PCR in a previous study. In addition, the results of this CRISPR-based system could be acquired within 75 min. Our isothermal diagnostic method with promising performance provides more convenience than PCR-based methods for detection and screening.IMPORTANCEA method for Neisseria gonorrhoeae (NG)/ Chlamydia trachomatis (CT) detection is developed using multiplex-recombinase polymerase amplification and Cas12a/Cas13a. This method can detect NG and CT simultaneously with high sensitivity and specificity. This method has great potential to be further developed into larger-scale screening and point-of-care testing (POCT).
Keyphrases
- crispr cas
- genome editing
- real time pcr
- image quality
- dual energy
- computed tomography
- contrast enhanced
- loop mediated isothermal amplification
- label free
- positron emission tomography
- magnetic resonance imaging
- genome wide
- high throughput
- nucleic acid
- mass spectrometry
- depressive symptoms
- magnetic resonance
- single cell
- physical activity
- early onset
- structural basis