Operative management of stress-positive minimally displaced lateral compression type 1 (LC1) pelvic ring injuries: Analysis of outcomes before and after implementation of a departmental stress protocol.
Nicholas J TuckerBryan L ScottAustin HeareStephen C StaceyCyril MauffreyJoshua Alan ParryPublished in: Journal of orthopaedic trauma (2023)
Implementation of a LSR protocol to determine management of minimally displaced stress-positive LC1 injuries was associated with increased rates of operative management, PT clearance by discharge, and a reduction in the number of patients discharging to rehabilitation facilities.