Cannulated screws fixation for nondisplaced femoral neck fractures: early versus late weight-bearing-a prospective analysis.
Donato CarolaGiuliano LattanziLetizia SenesiDaniele MassettiAntonio Pompilio GiganteRaffaele PascarellaSimone CerbasiPublished in: European journal of orthopaedic surgery & traumatology : orthopedie traumatologie (2024)
Postoperative complications, mortality and revision rate were higher in patients who followed a late-loaded rather than early loaded rehabilitation protocol. Functional outcome at 1-year survival is not significantly different. In nondisplaced intracapsular hip fractures treated with cannulated screws, an immediate full load should be preferred. Query.