Introduction: Colorectal cancer has a high prevalence and mortality rate in the United Kingdom. Cancerous colorectal lesions often bleed into the gastrointestinal lumen. The faecal immunochemical test (FIT) detects haemoglobin (Hb) in the faeces of patients and is used as a first line test in the diagnosis of colorectal cancer. Materials and Methods: A retrospective audit of all FIT performed and all colorectal cancers diagnosed in the Hull and East Riding of Yorkshire counties of the United Kingdom (population approximately 609,300) between 2018 and 2022 was conducted. FIT were performed using a HM-JACKarc analyser from Kyowa medical. The predominant symptom suggestive of colorectal cancer which prompted the FIT was recorded. Colorectal cancer was diagnosed using the gold standard of histological biopsy following colonoscopy. Results: Between 2018 and 2022, 56,202 FIT were performed on symptomatic patients. Follow on testing identified 1,511 with colorectal cancer. Of these people, only 450 people with a confirmed colorectal cancer had a FIT within the 12 months preceding their diagnosis. Of these 450 FIT results, 36 had a concentration of <10 μg/g and may be considered to be a false negative. The sensitivity of FIT in the patients identified was 92.00%. The most common reason stated by the clinician for a FIT being performed in patients with colorectal cancer was a change in bowel habits, followed by iron deficient anaemia. The number of patients diagnosed with colorectal cancer decreased in 2020, but increased significantly in 2021. Discussion: This study shows that 8.00% of people diagnosed with colorectal cancer in the Hull and East Riding of Yorkshire regions had a negative FIT. This study also shows that the SARS-CoV-2 pandemic affected the number of people diagnosed with colorectal cancer, and therefore skews the prevalence and pre-test probability of a positive test. There are many reasons why a FIT could produce a false negative result, the most likely being biological factors affecting the stability of haemoglobin within the gastrointestinal tract, or pre-analytical factors influencing faecal sampling preventing the detection of haemoglobin. Some colorectal lesions do not protrude into the gastrointestinal lumen and are less likely to bleed. Conclusion: This is the first study showing data from outside of a structured clinical trial and provides the largest study to date showing the sensitivity of FIT in a routine clinical setting. This study also provides evidence for the impact COVID-19 had on the rate of colorectal cancer diagnosis.
Keyphrases
- end stage renal disease
- sars cov
- newly diagnosed
- ejection fraction
- clinical trial
- chronic kidney disease
- coronavirus disease
- healthcare
- peritoneal dialysis
- risk factors
- cardiovascular disease
- type diabetes
- patient reported outcomes
- cross sectional
- ultrasound guided
- open label
- quantum dots
- young adults
- sensitive detection
- loop mediated isothermal amplification
- iron deficiency
- fine needle aspiration