Login / Signup

CT of Kidney Volume in Autosomal Dominant Polycystic Kidney Disease: Accuracy, Reproducibility, and Radiation Dose.

Micheli U BevilacquaCameron J HagueAlexandra RomannHana SheittDragoş Mihai VasilescuTae Won YiAdeera Levin
Published in: Radiology (2019)
Background Total kidney volume (TKV) assessment is valuable in autosomal dominant polycystic kidney disease (ADPKD) but the reference standard method of MRI planimetry requires access to MRI and time-consuming interpretation. Purpose To determine whether accurate TKV measurements comparable to the resource-intensive reference standard of MRI planimetry can be obtained by using alternate methods including dose-reducing CT protocols and time-saving measurement equations. Materials and Methods In this prospective study conducted September 2016 to June 2017, adult participants with ADPKD underwent one MRI and two CT examinations. Low-dose (LD) and ultra-low-dose (ULD) CT examinations were performed with radiation doses 1.4 and 2.6 times lower, respectively, than the authors' institution's standard abdomen and pelvis CT. ULD CT examinations were reconstructed via model-based iterative reconstruction. Three TKV measurement equations were applied to all image sets, and MRI manual planimetry was the reference standard. Spearman correlation with the reference standard, simple linear regression, and root mean square error (RMSE) calculation analyzed accuracy of these methods; intraclass correlation coefficient examined reproducibility. Results Thirty participants (mean age, 41 years; age range, 24-67 years) had a mean TKV of 1368.9 mL ± 1146.13 (standard deviation). The ULD and LD CT protocols had median dose-length product of 58.8 and 115.5 mGy ∙ cm, respectively (P = .01), and CT dose index of 1.2 and 3.9 mGy, respectively (P < .001). All imaging modalities and measurement equations had excellent correlation with the reference standard (r2 > 0.98). RMSE ranged from 80.5 to 157.3 mL (5.9%-11.5% of mean TKV). Intraclass correlation coefficients were greater than 0.98 for all methods. Mean measurement times for the ellipsoid method ranged from 4.6 to 5.2 minutes compared with a mean of 27.7 minutes (range, 14-60 minutes) for manual planimetry. Conclusion Accurate and reproducible total kidney volume measurements comparable to the reference standard of MRI planimetry can be obtained by using a dose-minimizing ultra-low-dose CT protocol and volume measurement based on discrete linear measurements. © RSNA, 2019 Online supplemental material is available for this article.
Keyphrases