Endoscopic ultrasound-guided biopsy using a three-prong asymmetry tip needle for pancreatic tumors and peridigestive tract lesions: Retrospective single-center study.
Kento ShionoyaRyosuke TonozukaShuntaro MukaiTakayoshi TsuchiyaReina TanakaKenjiro YamamotoKazumasa NagaiYukitoshi MatsunamiHiroyuki KojimaTakao ItoiPublished in: Journal of hepato-biliary-pancreatic sciences (2024)
The three-prong asymmetry tip needle demonstrated good diagnostic capability and adequate sample volume with safety for pancreatic, subepithelial, and other organ lesions.