Improved positional accuracy of dental implant placement using a haptic and machine-vision-controlled collaborative surgery robot: A pilot randomized controlled trial.

Jun-Yu ShiBei-Lei LiuXin-Yu WuMin LiuQi ZhangHong-Chang LaiMaurizio S Tonetti
Published in: Journal of clinical periodontology (2023)
Robot-assisted implant placement enabled greater positional accuracy of the implant compared to freehand placement in this pilot trial. The robotic system should be further developed to simplify surgical procedures and improve accuracy and be validated in properly sized trials assessing the full spectrum of relevant outcomes.