Surface Point Cloud Ultrasound with Transcranial Doppler: Coregistration of Surface Point Cloud Ultrasound with Magnetic Resonance Angiography for Improved Reproducibility, Visualization, and Navigation in Transcranial Doppler Ultrasound.
Joseph Nathaniel StemberK L TerilliE PerezM MegjhaniC A CooperS JambawalikarS ParkPublished in: Journal of digital imaging (2021)
Transcranial Doppler (TCD) ultrasound is a standard tool used in the setting of recent sub-arachnoid hemorrhage (SAH). By tracking velocity in the circle-of-Willis vessels, vasospasm can be detected as interval velocity increase. For this disease process, repeated TCD velocity measurements over many days is the basis for its usefulness. However, a key limitation to TCD is its user dependence, which is itself largely due to the fact that exact information about probe positioning is lost between subsequent scans. Surface point cloud ultrasound (SPC-US) was recently introduced as a general approach combining ultrasound and three-dimensional surface imaging of patient + probe. In the present proof-of-principle demonstration, we have applied SPC-US to TCD and co-registered the skin surface with that from MRA images to provide a roadmap of the vasculature in 3D space for better speed, accuracy, reproducibility, and potential semi-automation of TCD. Collating the acronyms, we call the combined approach SPC-US-TCD. TCD of the M1 was obtained while three-dimensional photographic images were obtained with the Structure Sensor camera. MRA imaging was also obtained. SPC-US-TCD and corresponding MRA 3D reconstruction images were co-registered in MeshMixer using the skin surfaces for alignment. A cylinder the width of the TCD probe was placed over the fused images and aligned with the direction and orientation of the TCD probe to demonstrate the acoustic beam. In the fused images, the acoustic beam intersects the right M1 segment of the middle cerebral artery (MCA). The angle of insonation is well demonstrated and measurable in various planes. Distance measurements made in Blender localized the TCD probe position based on three skin surface landmarks, and tabulated orientation based on three angles along the corresponding directions. SPC-US-TCD provides valuable information that is otherwise not present in TCD studies. By co-registering SPC-US-TCD data with that from cross sectional vessel imaging, precise probe location relative to external skin surface landmarks as well as 3D vessel location relative to TCD probe placement offers the potential to provide a roadmap that improves exam reproducibility, speed of acquisition, and accuracy. The goal of future work is to demonstrate this improvement statistically by application to multiple patients and scans.
Keyphrases
- magnetic resonance imaging
- deep learning
- quantum dots
- magnetic resonance
- living cells
- optical coherence tomography
- convolutional neural network
- computed tomography
- high resolution
- middle cerebral artery
- blood flow
- ultrasound guided
- cross sectional
- end stage renal disease
- soft tissue
- contrast enhanced ultrasound
- subarachnoid hemorrhage
- brain injury
- ejection fraction
- healthcare
- staphylococcus aureus
- peritoneal dialysis
- newly diagnosed
- artificial intelligence
- cerebral blood flow
- patient reported
- candida albicans
- human health
- low cost