Login / Signup

Posterior semi-circular canal electrode misplacement in Goldenhar's syndrome.

Ashish CastellinoPabina RayamajhiRahul KurkureMohan Kameswaran
Published in: Cochlear implants international (2020)
Literature documents the incidence of electrode misplacement within the range of 0.2% to 5.8% with the superior SCC as the most common site, followed by the vestibule. In this report, we present the finding of electrode misplacement in the posterior SCC in a child with Goldenhar syndrome which was subsequently corrected. This child with bilateral congenital profound SNHL presented for unilateral cochlear implant surgery. Intraoperatively, the lateral SCC bulge, stapes, oval window, round window niche and pyramid were noted absent, leading to a surgical decision in favour of a subtotal petrosectomy. Using the aberrant facial nerve and jugular bulb as critical landmarks, a cochleostomy was performed in the posteroinferior aspect of the promontory bulge. Although electrode insertion was smooth and complete, NRT was absent in the presence of normal electrode impedance. A post-operative HRCT scan showed the electrodes in the posterior SCC. Repositioning of the electrodes was carried out by creating a new cochleostomy anteroinferior to the previous one. Complete correct electrode insertion was accomplished via this cochleostomy complimented by robust NRT tracings. Cochlear implant electrode insertion should be supported by correct identification of surgical landmarks. Intraoperative impedance testing and NRT help confirm device integrity and correct placement, the absence of which may raise the suspicion of malposition. In the presence of such a suspicion, the post-operative HRCT scan is a useful retrospective guide to corrective action, in a low-cost setting lacking intra-operative imaging facilities like X-ray, Fluoroscopy, Flat Panel CT & CBCT. Abbreviations, BERA: Brainstem Evoked Response Audiometry; CBCT: Cone Beam Computed Tomography; EAC: External Auditory Canal; ITD: Insertion Test Device; LSCS: Lower Segment Caesarean Section; MDT: Multi-Disciplinary Team; NICU: Neonatal Intensive Care Unit; NRT: Neural Response Telemetry; OAE: Oto-Acoustic Emissions; PIH: Pregnancy Induced Hypertension; SCC: Semi-Circular Canal; SNHL: Sensori-Neural Hearing Loss.
Keyphrases